
2025-11-02 01:12:53
醫用吊塔的(de)(de)防(fang)漏(lou)電(dian)(dian)(dian)(dian)(dian)(dian)與防(fang)觸(chu)電(dian)(dian)(dian)(dian)(dian)(dian)保(bao)護(hu)(hu)(hu)(hu)設(she)計(ji)(ji)筑(zhu)牢**防(fang)線。設(she)備(bei)采(cai)用雙重絕(jue)緣結構,電(dian)(dian)(dian)(dian)(dian)(dian)氣(qi)部件與金(jin)屬外殼之間設(she)置絕(jue)緣層,絕(jue)緣電(dian)(dian)(dian)(dian)(dian)(dian)阻值大于 100MΩ,可有效防(fang)止(zhi)漏(lou)電(dian)(dian)(dian)(dian)(dian)(dian)現(xian)象發生。電(dian)(dian)(dian)(dian)(dian)(dian)源系統配備(bei)剩(sheng)余電(dian)(dian)(dian)(dian)(dian)(dian)流動作保(bao)護(hu)(hu)(hu)(hu)器(RCD),當(dang)漏(lou)電(dian)(dian)(dian)(dian)(dian)(dian)流超過 30mA 時,可在 0.1 秒內(nei)迅速切斷電(dian)(dian)(dian)(dian)(dian)(dian)源,避免醫護(hu)(hu)(hu)(hu)人員與患者發生觸(chu)電(dian)(dian)(dian)(dian)(dian)(dian)事故。此外,所(suo)有電(dian)(dian)(dian)(dian)(dian)(dian)源插座均采(cai)用防(fang)觸(chu)電(dian)(dian)(dian)(dian)(dian)(dian)保(bao)護(hu)(hu)(hu)(hu)門設(she)計(ji)(ji),單(dan)孔插入時保(bao)護(hu)(hu)(hu)(hu)門自動閉合,只有當(dang)插頭同(tong)時插入時才(cai)會開啟,從源頭杜絕(jue)兒童(tong)或非專(zhuan)業人員誤觸(chu)觸(chu)電(dian)(dian)(dian)(dian)(dian)(dian)的(de)(de)風險。醫用吊橋承重能(neng)力強(qiang)勁,可穩定掛載呼吸機、輸液泵等多種重癥(zheng)監護(hu)(hu)(hu)(hu)設(she)備(bei)。湖(hu)北質量醫用吊塔多少(shao)錢

醫用(yong)吊塔(ta)的(de)散熱(re)設(she)(she)計確保(bao)設(she)(she)備(bei)長期穩(wen)定(ding)(ding)運行(xing)(xing)。電(dian)氣組件(jian)(jian)集中(zhong)區域(yu)采(cai)(cai)用(yong)鏤空(kong)散熱(re)結構,配合(he)導熱(re)性能良好(hao)的(de)鋁合(he)金殼體,能快速將熱(re)量散發出(chu)去,避(bi)免組件(jian)(jian)因過(guo)熱(re)導致性能下降或損壞。電(dian)源模塊內(nei)置(zhi)智(zhi)能溫控(kong)風(feng)扇(shan),當溫度(du)超過(guo)設(she)(she)定(ding)(ding)閾值時(shi)自動開(kai)啟,風(feng)扇(shan)采(cai)(cai)用(yong)靜音設(she)(she)計,不影響手(shou)術(shu)環境。散熱(re)系統經過(guo)嚴(yan)格的(de)熱(re)仿真測試與實際運行(xing)(xing)驗證,確保(bao)在滿負荷運行(xing)(xing)狀態下,設(she)(she)備(bei)內(nei)部溫度(du)始終控(kong)制在**范圍(wei)內(nei)。設(she)(she)備(bei)的(de)鎖定(ding)(ding)裝置(zhi)采(cai)(cai)用(yong)雙重(zhong)**設(she)(she)計,需(xu)同時(shi)操作兩個(ge)部件(jian)(jian)才能解(jie)鎖,防止誤碰導致懸(xuan)臂移(yi)動。定(ding)(ding)制醫用(yong)吊塔(ta)單價醫用(yong)吊塔(ta)的(de)麻醉氣體排放接口能及時(shi)排出(chu)麻醉廢氣,保(bao)護醫護人員健康(kang)。

設(she)備(bei)(bei)的故(gu)障預警與(yu)自(zi)(zi)診斷(duan)功能(neng)降低維護風險。醫用吊(diao)塔(ta)內置智(zhi)能(neng)診斷(duan)模塊,可對電(dian)(dian)源(yuan)電(dian)(dian)壓(ya)、氣(qi)體壓(ya)力(li)(li)、懸臂(bei)平(ping)衡狀態等 20 余項關鍵(jian)參數進(jin)行實(shi)時監測(ce),當檢測(ce)到參數異(yi)常時,會時間(jian)(jian)通過聲(sheng)光報警提示,并在(zai)顯示屏上顯示故(gu)障部位與(yu)排查建議。對于輕微(wei)故(gu)障,如接(jie)(jie)口松動、濾網(wang)堵塞等,設(she)備(bei)(bei)可自(zi)(zi)動進(jin)行初步修復;對于嚴重故(gu)障,則會啟動**保(bao)護程序(xu),切斷(duan)相關功能(neng)回(hui)路,防止故(gu)障擴大,為維護人員爭(zheng)取處理時間(jian)(jian)。氣(qi)體接(jie)(jie)口增設(she)牙(ya)科(ke)的壓(ya)縮空(kong)氣(qi)與(yu)負(fu)壓(ya)吸引接(jie)(jie)口,輸出壓(ya)力(li)(li)可在(zai) 0.2-0.8MPa 之間(jian)(jian)無(wu)級調節,滿(man)足牙(ya)科(ke)手機等設(she)備(bei)(bei)的不(bu)同(tong)壓(ya)力(li)(li)需求,同(tong)時配備(bei)(bei)管(guan)路過濾器,防止雜質進(jin)入設(she)備(bei)(bei)造成損壞。
針對不同(tong)手(shou)術(shu)場景(jing)的需求,醫(yi)用(yong)(yong)(yong)吊塔(ta)推出多種(zhong)功(gong)能模塊與組(zu)合形式。腔(qiang)(qiang)鏡(jing)吊塔(ta)可集成腔(qiang)(qiang)鏡(jing)主機、高清(qing)顯示器、冷光源(yuan)(yuan)(yuan)等(deng)設備(bei)的安裝平(ping)臺與連接(jie)(jie)接(jie)(jie)口,懸臂(bei)(bei)采用(yong)(yong)(yong)可伸縮設計(ji),能根(gen)據腔(qiang)(qiang)鏡(jing)手(shou)術(shu)操作(zuo)距離靈活(huo)調整,同(tong)時配(pei)備(bei)專(zhuan)用(yong)(yong)(yong)線纜管理槽,避免(mian)線路纏(chan)繞打結。急(ji)救型吊塔(ta)則(ze)強(qiang)化了應急(ji)功(gong)能配(pei)置(zhi),除常規(gui)電(dian)(dian)源(yuan)(yuan)(yuan)與氣體接(jie)(jie)口外(wai),額外(wai)增設應急(ji)電(dian)(dian)源(yuan)(yuan)(yuan)接(jie)(jie)口與快速(su)呼(hu)叫系統,可直(zhi)接(jie)(jie)聯(lian)動護士站,在突(tu)發(fa)狀(zhuang)況下(xia)為醫(yi)護人員爭(zheng)取寶(bao)貴時間(jian)。此外(wai),還有(you)單臂(bei)(bei)、雙臂(bei)(bei)、三臂(bei)(bei)等(deng)多種(zhong)懸臂(bei)(bei)組(zu)合可選,適配(pei)從普通外(wai)科手(shou)術(shu)到復(fu)雜介(jie)入手(shou)術(shu)的各(ge)類(lei)手(shou)術(shu)室布局(ju)。醫(yi)用(yong)(yong)(yong)吊塔(ta)配(pei)備(bei)醫(yi)用(yong)(yong)(yong)監護儀(yi)平(ping)臺,承(cheng)重達 50kg,可**放置(zhi)監護設備(bei)。

醫用吊(diao)(diao)塔可(ke)在溫度 5-40℃、相(xiang)對濕度 30%-85% 的環境中(zhong)正常(chang)工作,適應不(bu)同地區**的氣(qi)候條件。電源系(xi)統支持(chi)寬電壓輸入,可(ke)在 180-240V 電壓范(fan)圍內穩(wen)定(ding)運行(xing),不(bu)受區域供電電壓波動影響。表(biao)面涂層具備(bei)良好的耐高(gao)低溫性(xing)能(neng)與(yu)抗老化(hua)性(xing)能(neng),長(chang)(chang)期使用后仍能(neng)保(bao)持(chi)色澤與(yu)性(xing)能(neng)穩(wen)定(ding),不(bu)會出現開裂、脫落等(deng)問題,確保(bao)設備(bei)在各類環境下的可(ke)靠性(xing)。針對教學與(yu)科(ke)研(yan)需求(qiu),醫用吊(diao)(diao)塔具備(bei)相(xiang)應的功能(neng)配置(zhi)。可(ke)集成高(gao)清攝像接口與(yu)視頻錄制系(xi)統,能(neng)實(shi)時(shi)采集手術(shu)過程(cheng)影像,通過網絡傳輸至示教室(shi)或科(ke)研(yan)平(ping)臺,支持(chi)多人同時(shi)觀看與(yu)實(shi)時(shi)討論。醫用吊(diao)(diao)橋強度高(gao)的鋁(lv)合金框架使其能(neng)在長(chang)(chang)期使用中(zhong)保(bao)持(chi)結構穩(wen)定(ding)。定(ding)制醫用吊(diao)(diao)塔單(dan)價
醫(yi)用吊塔的電(dian)纜和(he)氣管采用隱藏式設(she)計,讓外觀(guan)更(geng)整潔,減少細菌滋生空間。湖北質量醫(yi)用吊塔多少錢
針(zhen)對(dui)重(zhong)(zhong)癥(zheng)監護(hu)(hu)室(ICU)的(de)特殊(shu)需求,醫(yi)用(yong)吊塔推(tui)出 ICU 型(xing)號。該(gai)型(xing)號強(qiang)化了多設(she)備集成(cheng)能力,可(ke)同時安裝(zhuang)(zhuang)監護(hu)(hu)儀、呼吸機、輸(shu)液泵、營養泵等多種重(zhong)(zhong)癥(zheng)監護(hu)(hu)設(she)備,配(pei)備充足的(de)電源(yuan)(yuan)與氣體(ti)(ti)接口(kou),滿足重(zhong)(zhong)癥(zheng)患(huan)者(zhe)的(de)持(chi)(chi)續監測與診療(liao)需求。懸臂采用(yong)可(ke)折疊(die)設(she)計,在患(huan)者(zhe)轉運(yun)或床(chuang)單位清潔(jie)時可(ke)折疊(die)收(shou)納,節省空間。此(ci)外,還集成(cheng)了床(chuang)頭信(xin)息(xi)屏安裝(zhuang)(zhuang)架(jia),可(ke)顯示患(huan)者(zhe)基本信(xin)息(xi)、監護(hu)(hu)數據與診療(liao)方案,為(wei)醫(yi)護(hu)(hu)人員提供多方面的(de)患(huan)者(zhe)信(xin)息(xi)支持(chi)(chi)。電源(yuan)(yuan)插(cha)座帶有(you)保護(hu)(hu)蓋(gai),未(wei)使用(yong)時自動閉(bi)合,防(fang)止(zhi)液體(ti)(ti)滲入(ru)與異(yi)物進入(ru),同時設(she)有(you)防(fang)觸電保護(hu)(hu)裝(zhuang)(zhuang)置,兒童或非專(zhuan)業人員無法(fa)隨(sui)意插(cha)入(ru)插(cha)頭。湖北質量醫(yi)用(yong)吊塔多少錢